HSL 103

Latch bolt lock with coupling mechanism

The HSL 103 lock is equipped with an RFID engageable rotary knob and proven HSL locking mechanism that can be recoded.

In the standard version, the lock has conventional I/O contacts for activation and evaluation. The higher-quality version has BUS connections.

Functional description

SECURE ACCESS CONTROL. DIRECTLY AT THE LOCK OR REMOTELY.

The latchbolt is operated via a rotary knob, which is activated via a coupling mechanism. When the coupling mechanism is deactivated, the rotary knob can be turned freely.

Coupling is activated locally using encrypted security RFID identification media (card/chip) via the outside module or via external control signals. Optionally, the coupling mechanism can be activated via a separate inmate button or cell call terminal.

In the event of a power failure or malfunction, the lock can be operated using the HSL double-bit key.

The available fittings (rotary knob and RFID outside module) are designed to prevent the attachment of cords or ropes and thus reduce the possibility of suicidal acts.

 

Re-coding the lock

The locking mechanism can be re-coded to a different locking when it is unlocked (bolt withdrawn). This requires a key of the current locking and a key of the future locking.

Features

The HSL 103 lock is equipped with an RFID engageable rotary knob and proven HSL locking mechanism that can be recoded.

In the standard version, the lock has conventional I/O contacts for activation and evaluation. The higher-quality version has BUS connections.

Application areas

The HSL 103 can be used in both detention room doors and passage doors. Power is supplied via a continuous power source or via a battery integrated in the RFID outside module. Interlock functions can be set up just as easily as inmate locking via RFID medium.

Overview

  • Designed for detention room and passage doors, patient room doors
  • Integration into PLC and GMS systems (BUS version)
  • Latch bolt operation via coupling mechanism
  • Coupling mechanism activation via RFID medium or remote
  • Manual emergency locking with HSL double-bit key (1-turn)
  • Lock can be re-coded without tools

Product locations

  • Passage door
  • Detention room door
  • Psychiatry patient door
  • Smoke protection door
Mobiler Select
Technical details
Options
Downloads

Technical details

Dimensions: (LxWxH) 200 x 22 x 220 mm
Forend dimension: (LxWxH) 280 x 30 x 4 mm
Latchbolt throw: 20 mm
Latchbolt material: Stainless steel casting
Latchbolt finishing: sliding coated
Lock case material: Stainless steel
Finishing: matt
Weight: 3.5 kg
Locking system: HSL double-bit lever system
Levers: 7
mechanically re-codable: yes
mechanical bolt position indicator: no
max. side load bolt forces: 10 kN
max. end load latchbolt counterforce: 2,5 kN
Number of audited locking operations: 500,000
Supply voltage: 24V DC
max. power consumption: 1500 mA
Operating temperature: -40°C up to +65°C
Storage temperature: -40°C up to +65°C
Relative humidity: 95% non condensing
IP protection class: X4 in installed state, in closed door body, with weather protection cover if necessary
Control inputs: Lock locked / unlocked Locking system interlock active / inactive
Sensor outputs: Door open / closed End position open / closed Locking mechanism locked / unlocked Sabotage/Disruption

Options

The following equipment options are available for the HSL 103 lock type:

  • S1 | Main Locking Mechanism: Lockable on one side
  • S2 | Main Locking Mechanism: Lockable on both sides
  • DR | DIN direction: right hand
  • DL | DIN direction: left hand
  • OA | Opening direction: outward
  • OE | Opening direction: inward
  • SK | Special forend: angular
  • CO | Connection for conventional I/O contacts (Dry contacts)
  • CB | Connection for BUS control
  • CT | Connection for BUS control and transponder reader
  • MF | Magnet in latchbolt: lateral
  • PS | Production lock (dummy lock without tumbler lock mechanism)

S1 | Main Locking Mechanism: Lockable on one side

The key guide of the main locking mechanism is located on one side of the lock. This equipment is used e.g. for detention room locks.

Configurable options

  • Lockable on one side
  • Lockable on both sides

S2 | Main Locking Mechanism: Lockable on both sides

The key guide of the main locking mechanism is located on both sides of the lock. This equipment is used e.g. for passage doors.

Configurable options

  • Lockable on one side
  • Lockable on both sides

DR | DIN direction: right hand

If the hinges are on the right side of the door, it is the "DIN right" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

DL | DIN direction: left hand

If the hinges are on the left side of the door, it is the "DIN left" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

OA | Opening direction: outward

Required specification for one-sided closing locks with deadbolt latch or deadbolt and latch. This applies e.g. to lock types HSL 102 and 104 with feature S1.

OE | Opening direction: inward

Required specification for one-sided closing locks with deadbolt latch or deadbolt and latch. This applies e.g. to lock types HSL 102 and 104 with feature S1.

SK | Special forend: angular

The forend is square at both ends and not round.

Configurable options

  • Standard forend: round
  • Special forend: angular
  • Special forend: extra wide
  • Special forend: extra long

CO | Connection for conventional I/O contacts (Dry contacts)

The lock has floating contacts (Dry Contact) for connection to PLC controls or a STUV door control. Large variety of I/O devices available for almost all applications.

  • with floating contacts (Dry Contact)

CB | Connection for BUS control

The lock has a BUS connection. BUS (Binary Unit System) is a data transmission system for the standardised connection of decentrally arranged devices, locks and readers, the so-called bus participants. The line-saving basic principle is that all bus participants can be connected to one bus line and exchange signals for opening, closing, signalling and monitoring on this line.

Benefits

  • Flexibility: If changes need to be made to the door control functions, there is no need to reinstall, only to reprogram
  • Simultaneous use of information: Information from one detector can be used in many places (e.g. opening of a detention room, simultaneous switching on or off of the detention room lighting, signalling of the open door via a signal light)

CT | Connection for BUS control and transponder reader

Connection for BUS control and transponder reader

MF | Magnet in latchbolt: lateral

With a reed contact (provided by the customer) in the frame, this feature enables electronic evaluation of the door's locking status (signal: latch bolt locked and door in frame). The magnets are mounted laterally in the latch and are visible. For this application, we recommend a functional test of the frames in conjunction with an on-site reed contact.

Configurable options

  • Bolt without magnet
  • Bolt with bar magnet
  • Latchbolt with magnet

PS | Production lock (dummy lock without tumbler lock mechanism)

Dummy lock available for door production without security features. The production lock will be charged. After a faultless return (inspection by STUV Prison Solutions), the amount minus shipping costs will be refunded or charged.

Downloads

miscellaneous

STUV-PRISON-HSL-103-RFID-DE PDF, 1,81MB

Do you have questions about a project?