HSL 104.RT

Motorised latch bolt lock with 2 HSL locking mechanisms and key switch function

The HSL 104.RT motorised lock is available with key guidance on one or both sides and is equipped with two mechanical HSL locking mechanisms. The latchbolt offers a locking travel of 20 mm. In the standard version, the lock has conventional I/O contacts for activation and evaluation; alternatively, it can be controlled via a BUS interface.

Functional description

The HSL 104.RT motorised lock is opened electrically via the upper HSL locking mechanism. The latchbolt is retracted by the motor. The lock can also be opened manually via the lower HSL locking mechanism of the latchbolt. The door can be opened manually or by an on-site door drive. Optionally, the opening process can be carried out via a PLC control unit supplied by the customer or by STUV.

As soon as the door swings out of the frame, the latch bolt moves motorised into the latch position (optionally depending on the design of the on-site control unit).

The door can be closed. As soon as the door is in the frame due to the latch function, the latch bolt is locked by motor. The door is completely locked.

Mechanical emergency unlocking is achieved by turning the HSL key through 180°, which disengages the motor, unlocks the integrated locking mechanism and retracts the latchbolt. The key can be removed while the door is open if the latchbolt is fully retracted.

 

Re-coding the lock

The upper and lower main locking mechanism can be switched to a different locking system when unlocked (latchbolt locked back).
This requires a key for the current locking mechanism and a key for the future locking mechanism.

 

Features

The HSL 104.RT motorised lock is available with key guidance on one or both sides and is equipped with two mechanical HSL locking mechanisms. The latchbolt offers a locking travel of 20 mm. In the standard version, the lock has conventional I/O contacts for activation and evaluation; alternatively, it can be controlled via a BUS interface.

Application areas

The type HSL 104.RT is designed for detention room and passage doors. Interlock functions can be easily set up by configuring the control unit.

Overview

  • Designed for detention room and passage doors, airlock doors
  • Integration into PLC systems
  • Latch bolt actuation via motor
  • Operation via HSL key via integrated key switch
  • Manual emergency locking with HSL double-bit key (1-turn)
  • Locking can be recoded without changeover key

Product locations

  • Passage door
  • Detention room door
  • Outer gate
  • Airlock door
  • Main entrance door
  • Smoke protection door
Mobiler Select
Technical details
Options
Downloads
Accessories

Technical details

Dimensions: (LxWxH) 210 x 32 x 397 mm (incl. lock box)
Forend dimension: (LxWxH) 458 x 30 x 4 mm
Bolt throw: 20 mm
Bolt material: Stainless steel casting
Bolt finishing: sliding coated
Lock case material: Stainless steel
Finishing: matt
Weight: 6.1 kg
Locking system: 2 x HSL-Doppelbart
Levers: 7
mechanically re-codable: yes
mechanical bolt position indicator: no
max. side load bolt forces: 50 kN
max. end load bolt counterforce: 2,5 kN
Number of audited locking operations: 1,500,000
Supply voltage: 24V DC
max. power consumption: 1500 mA
Operating temperature: -40°C up to +65°C
Storage temperature: -40°C up to +65°C
Relative humidity: 95% non condensing
IP protection class: X4 in installed state, in closed door body, with weather protection cover if necessary
Control inputs: Lock locked / unlocked Locking system interlock active / inactive
Sensor outputs: Door open / closed End position open / closed Locking mechanism locked / unlocked Sabotage/Disruption / key switch

Options

The following equipment options are available for the HSL 104.RT lock type:

  • S1 | Main Locking Mechanism: Lockable on one side
  • S2 | Main Locking Mechanism: Lockable on both sides
  • DR | DIN direction: right hand
  • DL | DIN direction: left hand
  • OA | Opening direction: outward
  • OE | Opening direction: inward
  • S5 | Special forend: 5 mm
  • KB | Locking mechanism interlock (energised locked) and query of the lock states with conv. I/O contacts
  • CO | Connection for conventional I/O contacts (Dry contacts)
  • MF | Magnet in latchbolt: lateral
  • AS | Removal barrier
  • PP | PowerPack for one-time motorised emergency locking in case of power failure
  • PS | Production lock (dummy lock without tumbler lock mechanism)

S1 | Main Locking Mechanism: Lockable on one side

The key guide of the main locking mechanism is located on one side of the lock. This equipment is used e.g. for detention room locks.

Configurable options

  • Lockable on one side
  • Lockable on both sides

S2 | Main Locking Mechanism: Lockable on both sides

The key guide of the main locking mechanism is located on both sides of the lock. This equipment is used e.g. for passage doors.

Configurable options

  • Lockable on one side
  • Lockable on both sides

DR | DIN direction: right hand

If the hinges are on the right side of the door, it is the "DIN right" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

DL | DIN direction: left hand

If the hinges are on the left side of the door, it is the "DIN left" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

OA | Opening direction: outward

Required specification for one-sided closing locks with deadbolt latch or deadbolt and latch. This applies e.g. to lock types HSL 102 and 104 with feature S1.

OE | Opening direction: inward

Required specification for one-sided closing locks with deadbolt latch or deadbolt and latch. This applies e.g. to lock types HSL 102 and 104 with feature S1.

S5 | Special forend: 5 mm

The forend is designed with a material thickness of 5 mm.

Configurable options

  • Standard forend: 4 mm

KB | Locking mechanism interlock (energised locked) and query of the lock states with conv. I/O contacts

The mechanical locking mechanism can be interlocked via conventional I/O contacts. Locking with the HSL key is not possible in this state. In addition, various lock states can be signalled:

  • Bolt extended / retracted
  • Lock / door in frame
  • Interlock active / inactive

Configurable options

  • Locking mechanism interlock (energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (energised locked) and status query of the lock states with Bus contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with Bus contacts

CO | Connection for conventional I/O contacts (Dry contacts)

The lock has floating contacts (Dry Contact) for connection to PLC controls or a STUV door control. Large variety of I/O devices available for almost all applications.

  • with floating contacts (Dry Contact)

MF | Magnet in latchbolt: lateral

With a reed contact (provided by the customer) in the frame, this feature enables electronic evaluation of the door's locking status (signal: latch bolt locked and door in frame). The magnets are mounted laterally in the latch and are visible. For this application, we recommend a functional test of the frames in conjunction with an on-site reed contact.

Configurable options

  • Bolt without magnet
  • Bolt with bar magnet
  • Latchbolt with magnet

AS | Removal barrier

The removal barrier prevents unauthorised removal of the lock when the door is open. The lock can only be removed when the locking elements are locked. Ergo, the double-bit key is absolutely necessary.

PP | PowerPack for one-time motorised emergency locking in case of power failure

The PowerPack is installed in the lock and works like a short-term battery. In the event of a power failure, a motorised lock can be opened or closed once.

Configurable options

  • without PowerPack (mechanical closing always guaranteed in case of power failure)
  • with PowerPack

PS | Production lock (dummy lock without tumbler lock mechanism)

Dummy lock available for door production without security features. The production lock will be charged. After a faultless return (inspection by STUV Prison Solutions), the amount minus shipping costs will be refunded or charged.

Downloads

miscellaneous

Technische Zeichnung HSL104.RT

Do you have questions about a project?