HSL 110

Deadbolt lock with
additional bolt

Deadbolt lock with additional bolt. It has a re-codable HSL tumbler locking system and is pre-equipped for an additional profile cylinder to operate the upper deadbolt. In the standard corridor side locking version, the lock has a mechanical locking status indication on the key guide side.

Prison high security lock HSL 110
Deadbolt
made of stainless steel
Mechanical locking status indicator
for lock status visualisation
HSL key guide
for door thicknesses up to 200 mm
Additional stainless steel bolt
Additional bolt operation
via profile cylinder

Functional description

The HSL double-bit key is inserted into the lock.

The bolt is withdrawn with the key via a single tour (180° turn).

The additional bolt is withdrawn with the profile cylinder key via a tour (360° turn).

The door can be opened.

The door is being closed.

The additional bolt is pre-locked with the profile cylinder key via a tour (360°). The profile cylinder key is being removed.

The bolt is pre-locked again with the HSL double-bit key via a single tour (180° turn). The key is removed.

The door is completely locked. The sequence of locking operations (main or additional deadbolt) is irrelevant for the operation of the lock.

Re-coding the lock

The HSL tumbler locking mechanism can be re-coded to a different locking when it is unlocked (bolt retracted). This requires a key of the current locking and a key of the future locking.

 

Features

Deadbolt lock with additional bolt. It has a re-codable HSL tumbler locking system and is pre-equipped for an additional profile cylinder to operate the upper deadbolt. In the standard corridor side locking version, the lock has a mechanical locking status indication on the key guide side.

Application areas

The lock type HSL 110 has been developed for special requirements in the correctional system. The upper deadbolt makes it possible to implement a four-eye principle by means of an extra profile cylinder. The keys can be removed in the standard variant in locked and unlocked state.

Overview

  • Developed for special locking requirements in the correctional system
  • Realisation of a four-eyes principle
  • additional deadbolt lock via profile cylinder
  • easy operation with HSL double-bit key (1 turn without follower)
  • Lock re-codable without tools

Product locations

  • Passage door
  • Detention room door
  • Custody door
  • Outer gate
  • Grid/fence door
Mobiler Select
Technical details
Options
Downloads
Accessories

Technical details

Dimensions: (LxWxH) 200 x 22 x 220 mm
Forend dimension: (LxWxH) 280 x 30 x 4 mm
Bolt throw: 20 mm
Additional bolt throw: 14 mm
Bolt material: Stainless steel casting
Additional bolt material: Stainless steel casting
Lock case material: Stainless steel
Finishing: matt
Weight: 3,4 kg
Locking system: HSL double-bit lever system
Levers: 7
mechanically re-codable: yes
mechanical bolt position indicator: yes, one-sided
max. side load bolt forces: 30 kN
max. side load additional bolt forces: 10 kN
max. end load bolt counterforce: 6 kN
max. end load additional bolt counterforce: 0,25 kN
Number of audited locking operations: 500,000
IP rating: IP65
Operating temperature: -40°C to +65°C
Storage temperature: -40°C to +65°C
Relative humidity: 95% non condensing

Options

The following equipment options are available for lock type HSL 110:

  • S1 | Main Locking Mechanism: Lockable on one side
  • S2 | Main Locking Mechanism: Lockable on both sides
  • DR | DIN direction: right hand
  • DL | DIN direction: left hand
  • SK | Special forend: angular
  • MK | Magnet in latch: front side
  • AS | Removal barrier
  • PS | Production lock (dummy lock without tumbler lock mechanism)
  • RI | Bolt position indicator: one-sided inverse

S1 | Main Locking Mechanism: Lockable on one side

The key guide of the main locking mechanism is located on one side of the lock. This equipment is used e.g. for detention room locks.

Configurable options

  • Lockable on one side
  • Lockable on both sides

S2 | Main Locking Mechanism: Lockable on both sides

The key guide of the main locking mechanism is located on both sides of the lock. This equipment is used e.g. for passage doors.

Configurable options

  • Lockable on one side
  • Lockable on both sides

DR | DIN direction: right hand

If the hinges are on the right side of the door, it is the "DIN right" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

DL | DIN direction: left hand

If the hinges are on the left side of the door, it is the "DIN left" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

SK | Special forend: angular

The forend is square at both ends and not round.

Configurable options

  • Standard forend: round
  • Special forend: angular
  • Special forend: extra wide
  • Special forend: extra long

MK | Magnet in latch: front side

With a reed contact (provided by the customer) in the frame, this feature enables the electronic evaluation of the locking status of the door (signal: bolt locked and door in frame). The two magnets are visible on the front side of the bolt.

Configurable options

  • Bolt without magnet
  • Bolt with bar magnet
  • Latchbolt with magnet

AS | Removal barrier

The removal barrier prevents unauthorised removal of the lock when the door is open. The lock can only be removed when the locking elements are locked. Ergo, the double-bit key is absolutely necessary.

PS | Production lock (dummy lock without tumbler lock mechanism)

Dummy lock available for door production without security features. The production lock will be charged. After a faultless return (inspection by STUV Prison Solutions), the amount minus shipping costs will be refunded or charged.

RI | Bolt position indicator: one-sided inverse

With the "inverse" equipment option, the indicator is in the opposite direction to the standard, i.e. when the bolt is closed, the indicator is retracted. Tightening torque of the locking status indicator: Ma= 6 Nm

For locks used without bolt position indicator, there is no drilling in the door leaf.

Configurable options

  • Bolt position indicator one-sided
  • Bolt position indicator on both sides
  • Bolt position indicator one-sided inverse
  • Bolt position indicator on both sides inverse

Downloads

miscellaneous

Technische Zeichnung HSL110M2

Do you have questions about a project?