HSL 111
Deadbolt / latch lock with daytime latch
In the standard version, the HSL 111 locks on one side, having a mechanical locking status indication on the key guide side. The indicator visualises the status of the main deadbolt.
Functional description
The HSL double-bit key is inserted into the lock.
The bolt is withdrawn with the key via a single tour (180° turn).
The additional day latch is retracted with the profile cylinder key via a tour (45° turn).
The door can be opened.
The profile cylinder key is removed. The additional day latch is in latch position.
The door is slammed shut.
The additional latch secures the door automatically when closing. The bolt is secured again with the HSL double-bit key via a single tour (180° turn).
The key is being removed.
The door is completely locked.
Re-coding the lock
The locking mechanism can be re-coded to a different locking when it is unlocked (bolt retracted). This requires a key of the current locking and a key of the future locking.
Features
In the standard version, the HSL 111 locks on one side, having a mechanical locking status indication on the key guide side. The indicator visualises the status of the main deadbolt.
Application areas
Type HSL 111 is designed for passage doors and storage room doors. The lock has two separate locking elements. The dead bolt is operated with the HSL double-bit key, the smaller additional latch is operated with a separately available profile cylinder. The additional latch cannot be operated with the HSL double-bit key. The lock type is used e.g. in workshop rooms rented by companies in the facility.
Technical details
Dimensions: (LxWxH) | 200 x 22 x 220 mm |
Forend dimension: (LxWxH) | 280 x 30 x 4 mm |
Bolt throw: | 20 mm |
Day latch throw: | 14 mm |
Bolt material: | Stainless steel casting |
Day latch material: | Stainless steel casting |
Oberfläche Fallenriegel: | sliding coated |
Lock case material: | Stainless steel |
Finishing: | matt |
Weight: | 3,3 kg |
Locking system: | HSL double-bit lever system |
Levers: | 7 |
mechanically re-codable: | yes |
mechanical bolt position indicator: | yes, one-sided |
max. side load bolt forces: | 30 kN |
max. side load day latch forces: | 10 kN |
max. end load bolt counterforce: | 6 kN |
Number of audited locking operations: | 500,000 |
IP rating: | IP65 |
Operating temperature: | -40°C to +65°C |
Storage temperature: | -40°C to +65°C |
Relative humidity: | 95% non condensing |
Technical drawing
Please log in to access the technical drawing.Options
The following equipment options are available for lock type HSL 111:
- S1 | Main Locking Mechanism: Lockable on one side
- S2 | Main Locking Mechanism: Lockable on both sides
- DR | DIN direction: right hand
- DL | DIN direction: left hand
- OA | Opening direction: outward
- OE | Opening direction: inward
- SK | Special forend: angular
- KB | Locking mechanism interlock (energised locked) and query of the lock states with conv. I/O contacts
- BB | Locking mechanism interlock (energised locked) and query of the lock states with BUS contacts
- CO | Connection for conventional I/O contacts (Dry contacts)
- CB | Connection for BUS control
- CT | Connection for BUS control and transponder reader
- MK | Magnet in latch: front side
- AS | Removal barrier
- PS | Production lock (dummy lock without tumbler lock mechanism)
S1 | Main Locking Mechanism: Lockable on one side
The key guide of the main locking mechanism is located on one side of the lock. This equipment is used e.g. for detention room locks.
Configurable options
- Lockable on one side
- Lockable on both sides
S2 | Main Locking Mechanism: Lockable on both sides
The key guide of the main locking mechanism is located on both sides of the lock. This equipment is used e.g. for passage doors.
Configurable options
- Lockable on one side
- Lockable on both sides
DR | DIN direction: right hand
If the hinges are on the right side of the door, it is the "DIN right" door opening.
Configurable options
- DIN direction: right
- DIN direction: left
DL | DIN direction: left hand
If the hinges are on the left side of the door, it is the "DIN left" door opening.
Configurable options
- DIN direction: right
- DIN direction: left
OA | Opening direction: outward
Required specification for one-sided closing locks with deadbolt latch or deadbolt and latch. This applies e.g. to lock types HSL 102 and 104 with feature S1.
OE | Opening direction: inward
Required specification for one-sided closing locks with deadbolt latch or deadbolt and latch. This applies e.g. to lock types HSL 102 and 104 with feature S1.
SK | Special forend: angular
The forend is square at both ends and not round.
Configurable options
- Standard forend: round
- Special forend: angular
- Special forend: extra wide
- Special forend: extra long
KB | Locking mechanism interlock (energised locked) and query of the lock states with conv. I/O contacts
The mechanical locking mechanism can be interlocked via conventional I/O contacts. Locking with the HSL key is not possible in this state. In addition, various lock states can be signalled:
- Bolt extended / retracted
- Lock / door in frame
- Interlock active / inactive
Configurable options
- Locking mechanism interlock (energised locked) and status query of the lock states with conv. I/O contacts
- Locking mechanism interlock (de-energised locked) and status query of the lock states with conv. I/O contacts
- Locking mechanism interlock (energised locked) and status query of the lock states with Bus contacts
- Locking mechanism interlock (de-energised locked) and status query of the lock states with Bus contacts
BB | Locking mechanism interlock (energised locked) and query of the lock states with BUS contacts
The mechanical locking mechanism can be interlocked via BUS contacts. Locking with the HSL key is not possible in this state. In addition, various lock states can be signalled:
- Bolt extended / retracted
- Lock / door in frame
- Interlock active / inactive
Configurable options
- Locking mechanism interlock (energised locked) and status query of the lock states with conv. I/O contacts
- Locking mechanism interlock (de-energised locked) and status query of the lock states with conv. I/O contacts
- Locking mechanism interlock (energised locked) and status query of the lock states with BUS contacts
- Locking mechanism interlock (de-energised locked) and status query of the lock states with BUS contacts
CO | Connection for conventional I/O contacts (Dry contacts)
The lock has floating contacts (Dry Contact) for connection to PLC controls or a STUV door control. Large variety of I/O devices available for almost all applications.
- with floating contacts (Dry Contact)
CB | Connection for BUS control
The lock has a BUS connection. BUS (Binary Unit System) is a data transmission system for the standardised connection of decentrally arranged devices, locks and readers, the so-called bus participants. The line-saving basic principle is that all bus participants can be connected to one bus line and exchange signals for opening, closing, signalling and monitoring on this line.
Benefits
- Flexibility: If changes need to be made to the door control functions, there is no need to reinstall, only to reprogram
- Simultaneous use of information: Information from one detector can be used in many places (e.g. opening of a detention room, simultaneous switching on or off of the detention room lighting, signalling of the open door via a signal light)
CT | Connection for BUS control and transponder reader
Connection for BUS control and transponder reader
MK | Magnet in latch: front side
With a reed contact (provided by the customer) in the frame, this feature enables the electronic evaluation of the locking status of the door (signal: bolt locked and door in frame). The two magnets are visible on the front side of the bolt.
Configurable options
- Bolt without magnet
- Bolt with bar magnet
- Latchbolt with magnet
AS | Removal barrier
The removal barrier prevents unauthorised removal of the lock when the door is open. The lock can only be removed when the locking elements are locked. Ergo, the double-bit key is absolutely necessary.
PS | Production lock (dummy lock without tumbler lock mechanism)
Dummy lock available for door production without security features. The production lock will be charged. After a faultless return (inspection by STUV Prison Solutions), the amount minus shipping costs will be refunded or charged.
Downloads
miscellaneous
Technische Zeichnung HSL111S2 | Login required |