HSL C101X

Compact deadbolt lock

Deadbolt lock for detention room doors with single turn bolt exclusion and mechanical bolt position indicator on the key guide side. As replacement lock for 8.13.0101.3/4 and 8.14.0120.3/4.

Functional description

The HSL double-bit key is inserted into the lock.

The bolt is locked back with the key via a tour (180° turn).

The detention door can be opened.

The detention door is closed.

The bolt is extended with the key via a tour (180° turn).

The detention door is fully locked.

 

Re-coding the lock

The locking mechanism can be re-coded to a different locking when it is unlocked (bolt retracted). This requires a key of the current locking and a key of the future locking.

Features

Deadbolt lock for detention room doors with single turn bolt exclusion and mechanical bolt position indicator on the key guide side. As replacement lock for 8.13.0101.3/4 and 8.14.0120.3/4.

Application areas

The type HSL C101X is designed as a replacement lock (retrofitting) for STUV single- and double bit locks and is used in custody doors. The bolt is locked forward and backward via one tour (180° key rotation). The key can be removed in locked and unlocked state.

Overview

  • 1:1 Replacement of old STUV single- and double-bit locks with HSL C
  • Easy operation with HSL double-bit key (1-turn)
  • Lock can be changed 9-fold without changeover key

Product locations

  • Detention room door
Mobiler Select
Technical details
Options
Downloads
Accessories

Technical details

Dimensions: (LxWxH) 137 x 22 x 180 mm
Forend dimension: (LxWxH) 330 x 30 x 4 mm
Bolt throw: 21 mm
Bolt material: Stainless steel
Lock case material: Stainless steel
Finishing: matt
Weight: 2,9 kg
Locking system: HSL double-bit
Levers: 7
mechanically re-codable: yes
mechanical bolt position indicator: yes, one-sided
max. side load forces: 30 kN
max. end load bolt counterforce: 6 kN
Number of audited locking operations: 500,000
IP rating: IP65
Operating temperature: -40°C to +65°C
Storage temperature: -40°C to +65°C
Relative humidity: 95% non condensing

Options

The following equipment options are available for lock type HSL C101X:

  • S1 | Main Locking Mechanism: Lockable on one side
  • DR | DIN direction: right hand
  • DL | DIN direction: left hand
  • AS | Removal barrier
  • PS | Production lock (dummy lock without tumbler lock mechanism)

S1 | Main Locking Mechanism: Lockable on one side

The key guide of the main locking mechanism is located on one side of the lock. This equipment is used e.g. for detention room locks.

Configurable options

  • Lockable on one side
  • Lockable on both sides

DR | DIN direction: right hand

If the hinges are on the right side of the door, it is the "DIN right" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

DL | DIN direction: left hand

If the hinges are on the left side of the door, it is the "DIN left" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

AS | Removal barrier

The removal barrier prevents unauthorised removal of the lock when the door is open. The lock can only be removed when the locking elements are locked. Ergo, the double-bit key is absolutely necessary.

PS | Production lock (dummy lock without tumbler lock mechanism)

Dummy lock available for door production without security features. The production lock will be charged. After a faultless return (inspection by STUV Prison Solutions), the amount minus shipping costs will be refunded or charged.