SL 105

Mechanical latch lock with auxiliary latch

In addition to the latch bolt, the lock has a smaller auxiliary latch. When the door is slammed to shut, the auxiliary latch secures the latch bolt.

Functional description

The lock has a latch bolt and an auxiliary latch. It is pre-equipped for use with a Euro profile cylinder.

The profile cylinder key is inserted into the cylinder. The latch bolt is withdrawn with the key via a tour (360° turn). The door can be opened. When the door is open, the latch bolt is pre-locked again via a tour (360° turn). The key is removed. After the passage, the door is pulled closed. The latch bolt falls into the opening provided for this purpose in the frame. The auxiliary latch is pressed into the lock via the strike plate. The latch bolt is deadlocked and the door is completely locked.

If the door is to remain unlocked, the key is removed with the latch bolt withdrawn.

Features

In addition to the latch bolt, the lock has a smaller auxiliary latch. When the door is slammed to shut, the auxiliary latch secures the latch bolt.

Application areas

This lock is designed for passage doors. In particular, doors with fire or smoke protection requirements can be implemented in conformity with this lock type. Feature ZS (forced locking) required.

Overview

  • designed for passage doors
  • Solution for doors with fire and smoke protection requirements
  • easy operation, pre-equipped for Euro profile cylinder

Product locations

  • Passage door
  • Grid/fence door
  • Main entrance door
  • Sports facilities door
  • Fire protection door
  • Smoke protection door
Mobiler Select
Technical details
Options
Accessories

Technical details

Dimensions: (LxWxH) 196,6 x 22,3 x 184,7 mm
Forend dimension: (LxWxH) 280 x 30 x 4 mm
Latch bolt throw: 20 mm
Latch bolt material: Stainless steel casting
Latch bolt finishing: sliding coated
Lock case material: Stainless steel
Finishing: matt
Weight: 2,7 kg
pre-equipped for: Euro profile cylinders
mechanically re-codable: non
mechanical bolt position indicator: non
max. side load latch bolt forces: 10 kN
max. end load latch bolt counterforce: 2,5 kN
Number of audited locking operations: 500,000
Environmental class:: IP65
Operating temperature: -40°C to +65°C
Storage temperature: -40°C to +65°C
Relative humidity: 95% non condensing

Options

Optional features for lock type SL 105

  • DR | DIN direction: right hand
  • DL | DIN direction: left hand
  • DB | DIN direction: right and left
  • OA | Opening direction: outward
  • OE | Opening direction: inward
  • SK | Special forend: angular
  • KB | Locking mechanism interlock (energised locked) and query of the lock states with conv. I/O contacts
  • BB | Locking mechanism interlock (energised locked) and query of the lock states with BUS contacts
  • CO | Connection for conventional I/O contacts (Dry contacts)
  • CB | Connection for BUS control
  • MF | Magnet in latchbolt: lateral
  • ZS | Positive locking (key can only be removed when door is locked)
  • AS | Removal barrier
  • PS | Production lock (dummy lock without tumbler lock mechanism)

DR | DIN direction: right hand

If the hinges are on the right side of the door, it is the "DIN right" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

DL | DIN direction: left hand

If the hinges are on the left side of the door, it is the "DIN left" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

DB | DIN direction: right and left

Bolt locks that close on both sides can be used for both DIN right and DIN left doors. A specification when ordering is not required here. This applies e.g. to lock types HSL 101 and HSL 301 with feature S2.

OA | Opening direction: outward

Required specification for one-sided closing locks with deadbolt latch or deadbolt and latch. This applies e.g. to lock types HSL 102 and 104 with feature S1.

OE | Opening direction: inward

Required specification for one-sided closing locks with deadbolt latch or deadbolt and latch. This applies e.g. to lock types HSL 102 and 104 with feature S1.

SK | Special forend: angular

The forend is square at both ends and not round.

Configurable options

  • Standard forend: round
  • Special forend: angular
  • Special forend: extra wide
  • Special forend: extra long

KB | Locking mechanism interlock (energised locked) and query of the lock states with conv. I/O contacts

The mechanical locking mechanism can be interlocked via conventional I/O contacts. Locking with the HSL key is not possible in this state. In addition, various lock states can be signalled:

  • Bolt extended / retracted
  • Lock / door in frame
  • Interlock active / inactive

Configurable options

  • Locking mechanism interlock (energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (energised locked) and status query of the lock states with Bus contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with Bus contacts

BB | Locking mechanism interlock (energised locked) and query of the lock states with BUS contacts

The mechanical locking mechanism can be interlocked via BUS contacts. Locking with the HSL key is not possible in this state. In addition, various lock states can be signalled:

  • Bolt extended / retracted
  • Lock / door in frame
  • Interlock active / inactive

Configurable options

  • Locking mechanism interlock (energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (energised locked) and status query of the lock states with BUS contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with BUS contacts

CO | Connection for conventional I/O contacts (Dry contacts)

The lock has floating contacts (Dry Contact) for connection to PLC controls or a STUV door control. Large variety of I/O devices available for almost all applications.

  • with floating contacts (Dry Contact)

CB | Connection for BUS control

The lock has a BUS connection. BUS (Binary Unit System) is a data transmission system for the standardised connection of decentrally arranged devices, locks and readers, the so-called bus participants. The line-saving basic principle is that all bus participants can be connected to one bus line and exchange signals for opening, closing, signalling and monitoring on this line.

Benefits

  • Flexibility: If changes need to be made to the door control functions, there is no need to reinstall, only to reprogram
  • Simultaneous use of information: Information from one detector can be used in many places (e.g. opening of a detention room, simultaneous switching on or off of the detention room lighting, signalling of the open door via a signal light)

MF | Magnet in latchbolt: lateral

With a reed contact (provided by the customer) in the frame, this feature enables electronic evaluation of the door's locking status (signal: latch bolt locked and door in frame). The magnets are mounted laterally in the latch and are visible. For this application, we recommend a functional test of the frames in conjunction with an on-site reed contact.

Configurable options

  • Bolt without magnet
  • Bolt with bar magnet
  • Latchbolt with magnet

ZS | Positive locking (key can only be removed when door is locked)

The key cannot be removed when the lock is open. The operator is forced to pre-lock the locking element in order to remove the key from the lock. Passage doors with latch bolt or deadbolt latch with this equipment option only have to be pulled closed after passage. Locking then takes place automatically. The user only has to operate the lock on one side. A considerable time saving.

Configurable options

  • Standard: without positive closing

AS | Removal barrier

The removal barrier prevents unauthorised removal of the lock when the door is open. The lock can only be removed when the locking elements are locked. Ergo, the double-bit key is absolutely necessary.

PS | Production lock (dummy lock without tumbler lock mechanism)

Dummy lock available for door production without security features. The production lock will be charged. After a faultless return (inspection by STUV Prison Solutions), the amount minus shipping costs will be refunded or charged.

Do you have questions about a project?