SL 106

Deadbolt/latch lock with handle follower

Deadbolt lock with single turn deadbolt exclusion. The lock has a lever handle follower for operating the latch. In the standard corridor side locking version, the lock has a mechanical bolt position indicator on the key guide side.

Functional description

The profile cylinder key is inserted into the profile cylinder.

The bolt is withdrawn with the key via a tour (360° turn). This unlocks the lever handle at the same time.

The door can be opened by pressing the handle. This withdraws the latch.

The door is being closed.

During daytime operation, the bolt can remain withdrawn. In this state, the door can be opened by any person via the handle.

To lock the lever handle and completely lock the door, the bolt is pre-locked with the key via a tour (360° turn).

Features

Deadbolt lock with single turn deadbolt exclusion. The lock has a lever handle follower for operating the latch. In the standard corridor side locking version, the lock has a mechanical bolt position indicator on the key guide side.

Application areas

The type SL 106 is designed for administration, patient room and passage doors. The bolt is withdrawn and pre-locked via a tour (360° key rotation). The lever handle is blocked when the bolt is in locked state. The key can be removed in locked and unlocked state.

Overview

  • Handle/lever function for administration doors
  • lockable lever handle function
  • simple operation, pre-equipped for Euro profile cylinders

Product locations

  • Passage door
  • Technical room
  • Sanitary room
  • Psychiatry patient door
  • Administration door
Mobiler Select
Technical details
Options
Accessories

Technical details

Dimensions: (LxWxH) 200 x 22 x 220 mm
Forend dimension: (LxWxH) 280 x 30 x 4 mm
Bolt throw: 20 mm
Latch bolt throw: 14 mm
Bolt material: Stainless steel casting
Latch bolt material: Stainless steel casting
Latch bolt finishing: sliding coated
Lock case material: Stainless steel
Finishing: matt
Weight: 3,2 kg
Handle follower: 9 mm
pre-equipped for: Euro profile cylinder
mechanically re-codable: non
mechanical bolt position indicator: yes, one-sided
max. side load bolt forces: 30 kN
max. side load latch bolt forces: 10 kN
max. end load bolt counterforce: 6 kN
Number of audited locking operations: 500,000
Environmental class: IP65
Operating temperature: -40°C to +65°C
Storage temperature: -40°C to +65°C
Relative humidity: 95% non condensing

Options

The following equipment options are available for lock type SL 106:

  • DR | DIN direction: right hand
  • DL | DIN direction: left hand
  • DB | DIN direction: right and left
  • SK | Special forend: angular
  • KB | Locking mechanism interlock (energised locked) and query of the lock states with conv. I/O contacts
  • BB | Locking mechanism interlock (energised locked) and query of the lock states with BUS contacts
  • CO | Connection for conventional I/O contacts (Dry contacts)
  • CB | Connection for BUS control
  • MK | Magnet in latch: front side
  • AS | Removal barrier
  • PS | Production lock (dummy lock without tumbler lock mechanism)
  • RI | Bolt position indicator: one-sided inverse
  • ZA | Cylinder emergency release in the event of locking mechanism interlock (de-energised blocked)

DR | DIN direction: right hand

If the hinges are on the right side of the door, it is the "DIN right" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

DL | DIN direction: left hand

If the hinges are on the left side of the door, it is the "DIN left" door opening.

Configurable options

  • DIN direction: right
  • DIN direction: left

DB | DIN direction: right and left

Bolt locks that close on both sides can be used for both DIN right and DIN left doors. A specification when ordering is not required here. This applies e.g. to lock types HSL 101 and HSL 301 with feature S2.

SK | Special forend: angular

The forend is square at both ends and not round.

Configurable options

  • Standard forend: round
  • Special forend: angular
  • Special forend: extra wide
  • Special forend: extra long

KB | Locking mechanism interlock (energised locked) and query of the lock states with conv. I/O contacts

The mechanical locking mechanism can be interlocked via conventional I/O contacts. Locking with the HSL key is not possible in this state. In addition, various lock states can be signalled:

  • Bolt extended / retracted
  • Lock / door in frame
  • Interlock active / inactive

Configurable options

  • Locking mechanism interlock (energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (energised locked) and status query of the lock states with Bus contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with Bus contacts

BB | Locking mechanism interlock (energised locked) and query of the lock states with BUS contacts

The mechanical locking mechanism can be interlocked via BUS contacts. Locking with the HSL key is not possible in this state. In addition, various lock states can be signalled:

  • Bolt extended / retracted
  • Lock / door in frame
  • Interlock active / inactive

Configurable options

  • Locking mechanism interlock (energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with conv. I/O contacts
  • Locking mechanism interlock (energised locked) and status query of the lock states with BUS contacts
  • Locking mechanism interlock (de-energised locked) and status query of the lock states with BUS contacts

CO | Connection for conventional I/O contacts (Dry contacts)

The lock has floating contacts (Dry Contact) for connection to PLC controls or a STUV door control. Large variety of I/O devices available for almost all applications.

  • with floating contacts (Dry Contact)

CB | Connection for BUS control

The lock has a BUS connection. BUS (Binary Unit System) is a data transmission system for the standardised connection of decentrally arranged devices, locks and readers, the so-called bus participants. The line-saving basic principle is that all bus participants can be connected to one bus line and exchange signals for opening, closing, signalling and monitoring on this line.

Benefits

  • Flexibility: If changes need to be made to the door control functions, there is no need to reinstall, only to reprogram
  • Simultaneous use of information: Information from one detector can be used in many places (e.g. opening of a detention room, simultaneous switching on or off of the detention room lighting, signalling of the open door via a signal light)

MK | Magnet in latch: front side

With a reed contact (provided by the customer) in the frame, this feature enables the electronic evaluation of the locking status of the door (signal: bolt locked and door in frame). The two magnets are visible on the front side of the bolt.

Configurable options

  • Bolt without magnet
  • Bolt with bar magnet
  • Latchbolt with magnet

AS | Removal barrier

The removal barrier prevents unauthorised removal of the lock when the door is open. The lock can only be removed when the locking elements are locked. Ergo, the double-bit key is absolutely necessary.

PS | Production lock (dummy lock without tumbler lock mechanism)

Dummy lock available for door production without security features. The production lock will be charged. After a faultless return (inspection by STUV Prison Solutions), the amount minus shipping costs will be refunded or charged.

RI | Bolt position indicator: one-sided inverse

With the "inverse" equipment option, the indicator is in the opposite direction to the standard, i.e. when the bolt is closed, the indicator is retracted. Tightening torque of the locking status indicator: Ma= 6 Nm

For locks used without bolt position indicator, there is no drilling in the door leaf.

Configurable options

  • Bolt position indicator one-sided
  • Bolt position indicator on both sides
  • Bolt position indicator one-sided inverse
  • Bolt position indicator on both sides inverse

ZA | Cylinder emergency release in the event of locking mechanism interlock (de-energised blocked)

If the equipment options KU and BU "locking mechanism interlock de-energised" are selected, we additionally recommend the equipment option ZA. In the event of a power failure, this option overrides the locking mechanism interlock by the profile cylinder and enables a mechanical emergency release.

Do you have questions about a project?